CN
      CN

      PRODUCT CENTER

      PRODUCTS

      BACK
      DESCRIPTION
      PARAMETER

      Technical Feature  18 series

      Instruction

      Rated Voltage

      DC6V

      AC12V

      DC12V

      AC24V

      DC24V

      Coil resistance

      17.5Ω ±0.5Ω(20oC)

      17.5Ω ±0.5Ω(20oC)

      36Ω± 2Ω(20oC)

      40Ω± 2Ω(20oC)

      130Ω ±5Ω(20oC)

      Min current

      228mA

      480Ma

      300mA

      250mA

      166mA

      Switch mode

      DC pulse(latching type)

      AC and DC continuous(normal closed type)

      Pulse width

      ≥30ms

      Operating pressure

      0.02Mpa-0.8Mpa

      Media temperature

      1oC--75oC

      Responding time

      Open ≤0.15s close≤0.5s

      Performance test

      Strength test

      Static pressure 1.6MPa

      Withstand voltage pressure

      1.2MPa/5min

      No-load test

      Voltage 3.6V pulse width 30ms

      Permissible limiting voltage

      V*1.15

      High water pressure start and close

      At water pressure 0.8MPa,voltage DC4.5V,pulse width 30ms,the solenoid valve can be started and closed normally

      low water pressure start and close

      At water pressure 0.02MPa,voltage DC4.5V,pulse width 30ms,the solenoid valve can be started and closed normally

      Leakage upon high water pressure

      1.2MPa without leakage

      Leakage upon low water pressure

      0.02Mpa leakage≤0.1ml/min

      Electric strength

      Among conductive part, mounting hole and nonconductive metal, it can withstand 1500V/50Hz,leakage current 0.75mA for 1 min without the breakdown

      Insulation resistance

      The resistance between the charged part and nonconductive metal part tested by megohm meter of 500V ≥100MΩ

       

       

       

      Sealing test

       

       

       

      Static pressure

      Air

      High pressure

      1MPa

      Low pressure

      0.02MPa

      Cold water

      High pressure

      1.2MPa

      Low pressure

      0.02MPa

      Hot water

      High pressure

      0.8MPa

      Low pressure

      0.02MPa

      Service life

      ≥1000000 cycles(CJ/T 194-2004)

       

      Requirements of working environment

      Temp of working environment

      1℃--60℃

      Permissible limiting pressure(water)

      ≤1.2MPa

      Humidity of working environment

      35%-90% RH

      Mounting direction

      It is mounted in vertical. The inclination do not exceed 15 degrees

      Storage temp

      -5--80℃( no freezing state)

      Storage humidity

      25%--95% RH(No condensation state)


      PATENT
      SYSTEM
      DOWNLOAD

      COPYRIGHT ? 2020 Zhejiang Fuxin Electrical Technology Co., Ltd. ALL RIGHTS RESERVED   浙ICP備13032040號(hào)-1   Technical support: Jingke digital